N.C.
N.C.
N.O.
N.O.
2K
2K
N.C.
N.C.
N.O.
N.O.
2K
2K
N.C.
N.O.
2K
2-WIRE SMOKE DETECTOR LOOP
REMOTE KEYPAD.
OPTIONAL FOR
SLAVE DACT
INSTALLATIONS.
REQUIRED FOR
STAND ALONE
CONTROL
INSTALLATIONS.
YELLOW
GREEN
BLACK
RED
9
10 11
12
13 14 15
16
17 18
19
20
DATA OUT
DATA IN
GROUND
AUX. POWER +
ZONE 5 –
ZONE 5 +
ZONE 4 +
ZONE 3/ZONE 4 -
ZONE 3 +
ZONE 2 +
ZONE 1/ZONE 2 –
ZONE 1+
5110XM SUMMARY OF CONNECTIONS
THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE
PROTECTION ASSOCIATION’S STANDARD 72 (NATIONAL FIRE PROTECTION ASSOC.,
BATTERY MARCH PARK, QUINCY, MA 02269). PRINTED INFORMATION DESCRIBING
PROPER INSTALLATION, OPERATION, TESTING, MAINTENANCE, AND REPAIR SERVICE IS
PROVIDED WITH THIS EQUIPMENT.
WARNING:
OWNER’S INSTRUCTION NOTICE NOT TO BE REMOVED
Refer to the 5110XM Installation Instructions N8026
for additional information
MAY BE USED AS A SLAVE DACT PROVIDING CENTRAL OR REMOTE STATION SERVICE FOR A CENTRAL
OR REMOTE STATION UL LISTED FACP. MAY ALSO BE USED AS A STAND-ALONE NON-CODED LOCAL,
CENTRAL STATION AND REMOTE STATION PROTECTED PREMISES UNIT PROVIDING MANUAL FIRE
ALARM, AUTOMATIC FIRE ALARM, SPRINKLER SUPERVISORY AND WATER FLOW ALARM. INSTALLATION
LIMITS UNDER JURISDICTION OF LOCAL AUTHORITY.
ENCLOSED TRANSFORMER
(LOWER LEFT HAND CORNER OF 5110XM CABINET
REPLACE COVER AFTER WIRING
↓
SEE AC
TRANSFORMER
CONNECTIONS
ABOVE
(SUPERVISED)
NOTES:
Note 1:
Supervision may be disabled by cutting jumper W2 and
programming zone 6 for no response.
Note 2:
The combined standby current drawn from aux power
and relay power cannot exceed 350mA.
The combined alarm current drawn from aux power,
relay power and bell cannot exceed 1.0A
Note 3:
All circuits are power limited except transformer 18VAC
output.
CIRCUIT CONTROL UNIT SMOKE DETECTORS
(ZONE) DELAY - SEC MODEL DELAY - SEC
ZONE 1-5 NOTES:
• ALL ZONES PROVIDE STYLE B SUPERVISION
• ZONE RESISTANCE (EXCLUDING EOLR)
+ ZONES 1-4: 300 OHM MAX
+ ZONE 5: 100 OHMS MAX
• ZONE RESPONSE: 300-500 MILLISECOND
(ALL ZONES)
• ZONE 5 RATINGS: + 10-14VDC
+ 2 MA MAX FOR 2-WIRE SMOKE
DETECTORS. UP TO 16 DETECTORS OF TYPE
SPECIFIED IN INSTRUCTIONS MAY BE USED.
+ UL COMPATIBILITY ID: A
• 2K EOLR IS ADEMCO MODEL 610-7
ALARM DEVICE MANUFACTURING CO.
A DIVISION OF PITTWAY CORPORATION
165 Eileen Way, Syosset, New York, 11791
Copyright © 1996 PITTWAY CORPORATION
RJ31X
RJ31X
BACK-UP DIALER
PHONE JACK
COMPLIES WITH FCC RULES, PART 68
FCC REG. NO: AC398U-68192-AL-E
RINGER EQUIVALENCE: 0.7B
THE DELAY TIME MARKED ON THE INSTALLED
DETECTORS IS TO BE USED
BELL CIRCUIT SUPERVISION JUMPER
INTACT: SUPERVISED USING 2K EOLR
CUT: NOT SUPERVISED (NO EOLR USED)
W2
(WHITE)
AUXILIARY
RELAY
AC
SMOKE
AC
BELL+
BELL-
W3
(RED)
RELAY POWER
JUMPER
EARTH
GROUND
MAIN DIALER
PHONE JACK
BUZZER SILENCE SWITCH
PUSH ONCE TO SILENCE,
PUSH AGAIN TO RESET
LED INDICATOR BOARD
PLUG BOARD
INTO THE J5 9 PIN
HEADER AS SHOWN
AC POWER
(GREEN)
BATT TROUBLE
(YELLOW)
COMM FAIL
(YELLOW)
LINE FAULT
(YELLOW)
SILENCED
(YELLOW)
J5
WARNING BUZZER
ACTIVATES ON ALARMS,
SUPERVISORIES AND TROUBLES
– AUX POWER RATING: 10-14VDC,
350mA MAX, POWER LIMITED
NOT SUPERVISED UL
(SEE NOTE 2)
– 6137, 6137R, 6139 OR 6139R MAY
BE USED AS A REMOTE KEYPAD,
KEYPAD COLOR SUBJECT TO
APPROVAL OF LOCAL AUTHORITY.
ONLY 6139 OR 6139R MAY BE USED
TO PROGRAM PANEL
– REFER TO INSTRUCTIONS FOR
MAX # OF KEYPADS AND WIRE
LENGTH RESTRICTIONS.
KEYPAD CONNECTION NOT
SUPERVISED
}
MAKE CONNECTIONS TO SEPARATE TELEPHONE
LINES USING CABLES SUPPLIED. SUPERVISION
IS PROGRAMMABLE
WARNING: TO PREVENT RISK OF ELECTRICAL
SHOCK, DISCONNECT TELCO JACK
BEFORE SERVICING THIS PANEL
CONNECTION OF THE FIRE ALARM SIGNAL TO A
FIRE ALARM HEADQUARTERS OR A CENTRAL
STATION SHALL BE PERMITTED ONLY WITH
THE APPROVAL OF THE LOCAL AUTHORITY
HAVING JURISDICTION.
N8027 4/96
2K
MODEL
#610-7
– AUX RELAY HAS PROGRAMMABLE FUNCTION
(NOT SUPERVISED)
– JUMPER W3 INTACT: 10-14VDC ON TERMINAL 6
350mA MAX (STANDBY)/1A MAX (ALARM),
POWER LIMITED (SEE NOTE 2). USE TERMINAL 18
FOR GROUND RETURN.
– JUMPER W3 CUT: NO VOLTAGE ON TERMINAL 6.
RELAY CONTACT RATING: 30VAC/VDC,
2A MAX, RESISTIVE LOADS
– PROVIDES STYLE Y SUPERVISION
WHEN POLARIZED ALARM
DEVICES ARE USED (SEE NOTE 1)
– RATINGS:
10-14VDC,
1A MAX,
POWER LIMITED
(SEE NOTE 2)
BLUE
BLUE
N.O.
POLE/RELAY +
N.C.
GREEN
SEE
EARTH GROUND
CONNECTIONS
ABOVE
BATT –
BATT +
RED
BLACK
USE BATTERY CABLES
SUPPLIED
12V LEAD ACID BATTERY
7AH MIN/14 AH MAX.
SEE INSTRUCTIONS FOR
REQUIRED CAPACITY AND
BATTERY MOUNTING
FLOAT CHARGING
VOLTAGE: 13.7V
MAXIMUM CHARGING
CURRENT: 1.0A
BATTERY NORMALLY NEED
NOT BE REPLACED FOR AT
LEAST 3 YEARS
}
}
18VAC, 40VA NOT
POWER LIMITED.
CONNECT TO
AC POWER
TERMINALS 1, 2
MAINTAIN 1/4”
SPACING TO OTHER
WIRING.
120 VAC, 60Hz,
600mA MAX
CONNECT TO
A DEDICATED
CIRCUIT
NOTE: USE WIRES HAVING INSTALLATION
RATED FOR 90°C OR HIGHER
≈
≈
GREEN
GREEN
BLACK
BLUE
BLUE
WHITE
2A CIRCUIT
BREAKER
}
ALARM POLARITY SHOWN
BELL
HORN
1
2
3
4
8
5
CONNECT TO EARTH
GROUND TERMINAL 8
7
6
WARNING:
THIS UNIT MAY BE PROGRAMMED TO INCLUDE AN ALARM
VERIFICATION FEATURE THAT WILL RESULT IN A DELAY
OF THE SYSTEM ALARM SIGNAL FROM THE INDICATED
FIRE CIRCUITS. THE TOTAL DELAY (CONTROL UNIT PLUS
SMOKE DETECTORS) SHALL NOT EXCEED 60 SECONDS.
NO OTHER DEVICES SHALL BE CONNECTED TO THESE
CIRCUITS UNLESS APPROVED BY THE LOCAL AUTHORITY
HAVING JURISDICTION.
CONNECT TO
PROPER EARTH
GROUND. SEE
INSTRUCTIONS
BACK-UP
DIALER
LINE
SEIZE
(GREEN)
MAIN
DIALER
LINE
SEIZE
(GREEN)